Two logs, two limits
The tool prints one of two sheets. Choose Food business and the header reads "Cold holding limit: 41°F (5°C) or below", the figure in section 3-501.16 of the FDA Food Code. Choose Home and it reads "Fridge 40°F (4°C) or below, freezer 0°F (-18°C)", the FDA's advice for household appliances. Mixing them up is the most common mistake on downloaded logs, so the limit changes with the setting instead of sitting in fixed text.
| Where | Fridge | Freezer | Source |
|---|---|---|---|
| Home | 40°F (4°C) or below | 0°F (-18°C) | FDA consumer guidance |
| Restaurant, cafe, school kitchen | 41°F (5°C) or below | Set by your health code | FDA Food Code 3-501.16, as adopted by your state |
States and counties adopt the Food Code with their own edits, so your inspector's limit or check frequency can be stricter. When it is, print the log anyway and write their rule in the Location line.
Setting up the sheet
- Units to log. List up to four, separated by commas: "Walk-in, Reach-in, Bar fridge, Freezer". Each gets its own column under every check.
- Checks per day. One check prints a single reading block. Two gives opening and closing. Three adds midday. Each block has its own time column, because an inspector wants to see when you read it, not just what it said.
- Sheet covers. A month fits 31 numbered days on one landscape page. A week or two weeks gives taller rows, better for a home fridge or a log that also records notes.
- °F or °C. Column headings and the limit line switch together.
Taking a reading that means something
The dial inside most fridges is a setting from cold to colder, not a temperature. The FDA recommends an appliance thermometer, kept in the fridge and read at the same place each time. Write its ID in the header so a reading can be traced back to the thermometer that took it.
Read it before the door has been opened and closed many times; a reading taken during a delivery or a busy service will run high. If a reading is over the limit, write what you did in the last column: turned the setting down, moved food, called for repair. Then note the time you checked again and initial it. A log full of perfect numbers and no actions tends to raise more questions than one that shows a problem was caught and fixed.
Keeping the records
Clip the current month to the unit door or keep it on a board near the walk-in. File finished sheets by month. Your health department decides how long you must keep them; if they have not told you, ask at your next inspection. Because the sheet prints the date column already numbered, a missing day stands out at a glance.
Questions
What temperature should a fridge be?
The FDA says to keep a home refrigerator at 40°F (4°C) or below and a freezer at 0°F (-18°C). Restaurants and other food businesses follow the FDA Food Code, which sets cold holding at 41°F (5°C) or below.
Why is the home limit 40°F but the restaurant limit 41°F?
They come from two different FDA documents. The 40°F figure is consumer advice for home fridges. The 41°F figure is the cold holding limit in the Food Code that state and local health departments adopt for businesses. Use the one that applies to you; the log prints the right line for each.
How often should I check the temperature?
Many kitchens check at opening and closing; some add a midday check. Your health department may set a minimum, so ask them. The generator prints one, two or three checks per day.
What goes in the corrective action column?
Anything you did when a reading was too high: adjusted the setting, moved food to another unit, called for repair, threw food away. Add the time you re-checked and your initials.
Sources
- FDA: Refrigerator Thermometers, Cold Facts about Food Safety
- FDA Food Code (cold holding, section 3-501.16)
These sheets are a record-keeping aid, not legal, medical or safety advice. Check the rules that apply where you live or work.